INCA, the Insulated Render and Cladding Association, is a trade association for the external wall insulation industry formed in 1981. It is a voluntary body, not a legal requirement or a government register. If you are looking at quotes for external wall insulation, you will likely see the INCA name on installers' websites.
What the Insulated Render and Cladding Association is
The Insulated Render and Cladding Association is the recognised trade association for the external wall insulation (EWI) industry. INCA was formed in 1981 to represent this industry throughout the UK. The association represents three main groups: system designers, installers, and key component suppliers.
INCA says external wall insulation is a composite system made up of three basic components. The first is the insulant, which is typically expanded polystyrene or mineral fibre.
The second is a fixing to secure the insulation to the existing wall. The third is a finish, which is typically a render, a brick or stone effect finish or a cladding.
Is INCA membership a legal requirement?
INCA describes itself as the recognised trade association for the external wall insulation industry, and its pages describe a company applying to join. The pages do not present membership as a legal requirement. It is not a government register.
GOV.UK says an installer can join a competent person scheme to self-certify certain types of building work. It describes this as an alternative to getting building regulations approval.
INCA does not appear on that GOV.UK list, and a competent person scheme is a separate thing from a trade association. GOV.UK's page, last updated on 17 September 2026, lists BBA, Blue Flame Certification, CERTASS, Certsure and NAPIT as the schemes for external wall insulation in an existing building. Membership of INCA therefore does not show that an installer is on the GOV.UK scheme list.
The three types of INCA member
There are three distinct types of membership within INCA. The first is EWI Installers, who are the contractors that physically fit the insulation and render systems to buildings. The second is EWI System Designers, who create the specific combination of materials used in the insulation systems.
The third category is INCA Associates. INCA lists these as covering beads, trims and meter boxes, finishing products, fixings, insulation, testing and accreditation, and training partners.
What INCA says members must meet
Any company whose business is wholly or partly in the external wall insulation industry is eligible to apply for membership. Applicants must meet the required INCA criteria, and applications are considered by the INCA Board of Management, whose decision will be final. INCA says this process gives clients confidence they are working with a contractor that meets recognised standards of competence.
What INCA lists for system designers
On its page about choosing a member, INCA lists these for system designers: fully guaranteed systems, professional indemnity insurance, a UK based technical department, products supplied from a UK base and accredited EWI system certification. The page does not describe the guarantee terms.
What INCA lists for installers
INCA's page about its new installer code of practice lists membership criteria for installers, which it says are not part of the code. They include at least two years of active EWI trading, being an approved installer for at least one EWI system supplier, and the required insurance. They also include a satisfactory credit rating.
The list names SSIP accreditation, such as Veriforce or CHAS, and ISO 9001 or an equivalent quality system. It also names relevant sector registrations such as TrustMark. The page does not say that every member holds a particular registration.
The list also names references that INCA checks. On its page about choosing a member, INCA says installers show EWI reference projects, trade references, and quality, training and health and safety policies.
The INCA installer code of practice
INCA's page calls this a new EWI installer member code of practice, meant to help specifiers, contractors, clients and consumers identify trusted EWI professionals. INCA says all current installer members have signed up to it, and that it is a mandatory requirement for all new members.
The criteria above are separate from the code. The page states no launch date. INCA says the code includes sections on the following areas.
- Quality and Best Practice
- Guarantees
- Training and Competence
- Environmental and Sustainability Policy
- Health and Safety
- Legal and Regulatory Compliance
- Disputes and Conflict
- Integrity, Behaviour, Ethics and Communication
The page lists Guarantees as a section but does not describe the terms. The guarantee terms are in the PDF, not on the page.
What INCA membership proves and what it does not
The table below shows what INCA membership proves and what it does not.
|
What INCA membership proves |
What INCA membership does not prove |
|---|---|
|
The company has been accepted under INCA's criteria |
Quality of work on your wall |
|
For installers, they have signed the code of practice |
Any particular guarantee, or that the firm is on the GOV.UK scheme list |
How to look for an INCA member
The INCA EWI directory on INCA's site has a member type box. It filters results to an EWI Installer, an EWI System Designer or an INCA Associate.
INCA's page says the directory can also be filtered by size of works, with the options High Rise, Large Scale Works, Medium Size Works or Small Projects.
It can be filtered by area covered, or searched by city, county or postcode. After searching, ask the installer for their guarantee details and their certification in writing.
What INCA says about system certification
INCA's guide for homeowners says all INCA member EWI systems are covered by British Board of Agrément (BBA) certification.
It also says they are accredited to ISO9001 quality management standards and conform to all current building and EWI fire regulations.
The guide tells homeowners to consult the system designer's website for details and links to certification.
How INCA describes an installation
INCA's homeowner pages describe how an installation starts. A survey is required before work begins, and the quote for the works is based on it. INCA says a typical installation takes two to four weeks and that progress updates come from INCA contractors. INCA also says installation is weather dependent.
Common questions
Do you need planning permission for external wall insulation?
INCA's guide says that in most cases you will not require planning permission from your local council to install an EWI system. Its FAQs say planning permission is not required and is acceptable under permitted development if the final wall covering reflects that of the existing building, and that if the new finish varies it is likely planning permission is required.
INCA says permission is needed for a listed building, in a conservation area, or if the insulation thickness infringes into someone else's land or a public walkway or road. Its FAQs say permission is generally required in a designated area such as the green belt or countryside. INCA recommends always checking with the local planning office first.
How do you know if your house has solid walls?
INCA says solid walls are found in most houses built before the 1920s. On checking wall type, it says that if all the bricks are laid lengthways there is likely a cavity, while a mix of lengthways and end-on bricks usually means a solid wall.
INCA says solid walls measure in the region of 225mm thick, and that you can also consult your deeds or have a test hole drilled.
What U-values does INCA give for a solid brick wall?
INCA says a lower U-value means greater resistance to heat loss, and that a solid brick wall will typically have a U-value of 2.1W/m²K.
INCA provides approximate OFGEM numbers to demonstrate how different thicknesses of insulation improve this performance. Adding a 50mm layer of insulation takes the U-value down to 0.6W/m²K, and 100mm takes it to 0.35W/m²K. Increasing to 150mm drops the U-value to 0.25W/m²K, and 200mm of insulation takes it down to 0.18W/m²K.
What does a survey check before external wall insulation begins?
INCA's guide says a survey before work begins checks the suitability of the existing wall for mechanical fix, which will consist of a pull-out test.
The guide says the survey also covers reveals, windows and doors, overhang on cills and soffits, soil pipes and any existing coating that affects adhesion. It also lists what must be taken down and re-fixed, such as satellite dishes, meter boxes and gates. The quote for the works is based on the survey.
How long does external wall insulation take to install?
INCA says a typical installation will take two to four weeks, and that it is weather dependent. INCA contractors provide progress updates.
INCA's guide says render should not be applied in temperatures of 5 degrees and falling, nor in direct sun when the temperature is too high, usually around 25 degrees plus. Wet weather can also be a problem, so sheeting scaffolding to protect from the elements may be considered. Read the guide on plastering and rendering in cold weather for the plaster side.
What does INCA say about warranties?
INCA's guide says most system designers will be able to provide a warranty of, or in excess of, 25 years. It also says an INCA member contractor will be able to provide an insurance-backed guarantee. It says no EWI system is maintenance free but all are described as low-maintenance.
Does INCA membership mean a firm is on the GOV.UK scheme list?
No. GOV.UK's competent person scheme page does not mention INCA, and the two things are separate. INCA is a trade association for the EWI industry, formed in 1981. A competent person scheme is what GOV.UK describes as a way for an installer to self-certify certain types of building work.
Where are INCA's detailed membership criteria?
INCA's membership criteria page says any company whose business is wholly or partly in the external wall insulation industry is eligible to apply. It says applicants must meet the required INCA criteria and that the INCA Board of Management considers applications, and its decision will be final. The page does not list the detailed criteria, which are in a PDF titled INCA Membership Criteria Combined 2025.
Next steps
These steps follow what INCA's pages say about checking a member and the system. For costs and grants, read the guide on external wall insulation costs and grants.
- Search the INCA EWI directory by member type, size of works, and your area or postcode.
- Ask the installer for their guarantee details and their certification in writing.
- Look up the system designer's website to check the BBA certification for the specific materials being used.
- Check with your local planning office if your property is listed, in a conservation area, or if the new finish will look different from the existing walls.
- Read what INCA's guide says a survey checks before work begins, including a pull-out test.
You can find a plasterer near you on this site. The site lists plasterers and does not vet them, and listing says nothing about INCA membership.
Find a top rated plasterer near you
1,036 plasterers across the UK, each ranked on their Google rating and the number of reviews behind it. Start with your county: